CRITICALPhishing
Global

Toptech TMS7 and TopHAT

ยทSource: CISA Advisories

Updated:

Executive Summary

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access critical data or execute arbitrary code. The following versions of Toptech TMS7 and TopHAT are affected: TMS7 7.6.3 (CVE-2

Analysis

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access critical data or execute arbitrary code. The following versions of Toptech TMS7 and TopHAT are affected: TMS7 7.6.3 (CVE-2026-71379, CVE-2026-70356, CVE-2026-72510, CVE-2026-63713, CVE-2026-68954, CVE-2026-68068, CVE-2026-72507, CVE-2026-71302, CVE-2026-69662, CVE-2026-71189) TopHAT 7.6.3 (CVE-2026-71379, CVE-2026-70356, CVE-2026-72510, CVE-2026-63713, CVE-2026-68954, CVE-2026-68068, CVE-2026-72507, CVE-2026-71302, CVE-2026-69662, CVE-2026-71189) CVSS Vendor Equipment Vulnerabilities v3 10 Toptech Systems Toptech TMS7 and TopHAT Files or Directories Accessible to External Parties, Unrestricted Upload of File with Dangerous Type, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Session Fixation, Improper Neutralization of Directives in Dynamically Evaluated Code ('Eval Injection'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Energy, Chemical, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-71379 The file export endpoint allows any unauthenticated attacker to export arbitrary database tables by sending a crafted POST request. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H 4.0 10 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H CVE-2026-70356 The TMS file upload endpoint fails to enforce server-side file type restrictions, allowing an attacker to upload and execute arbitrary PHP files on the web server. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-434 Unrestricted Upload of File with Dangerous Type Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H 4.0 9.4 CRITICAL CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H CVE-2026-72510 The "supplier_no" parameter used in the business allocation search feature is vulnerable to time-based blind SQL injection. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H 4.0 8.5 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H CVE-2026-63713 The "search" parameter in the view audit logs feature within the utilities section is susceptible to a time-based blind SQL injection vulnerability. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H 4.0 8.5 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H CVE-2026-68954 The "pattern" parameter used in search function in the home page of the TMS application is vulnerable to time-based blind SQL injection vulnerability. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H 4.0 8.5 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H CVE-2026-68068 The "screenID" parameter in the electronic transaction queue viewer feature within the manual transactions section is susceptible to a time-based blind SQL injection vulnerability. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H 4.0 8.5 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H CVE-2026-72507 The "reportType" parameter in the product summary report feature within the balancing reports section is susceptible to a time-based blind SQL injection vulnerability. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H 4.0 8.5 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H CVE-2026-71302 The application accepts user-supplied session identifiers and does not regenerate the session ID after authentication. This allows an attacker to predefine a session ID and reuse it after victim authentication, resulting in session takeover. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-384 Session Fixation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L 4.0 7.5 HIGH CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N CVE-2026-69662 The application uses unsafe functions that allow execution of inline scripts and string evaluation functions. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-95 Improper Neutralization of Directives in Dynamically Evaluated Code ('Eval Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.7 LOW CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N 4.0 2.1 LOW CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N CVE-2026-71189 An attacker can construct a request that, if issued by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application. View CVE Details Affected Products Toptech TMS7 and TopHAT Vendor: Toptech Systems Product Version: Toptech Systems TMS7: 7.6.3, Toptech Systems TopHAT: 7.6.3 Product Status: known_affected Remediations Mitigation Toptech Systems sent a security advisory to their customers on July 20, 2026. The issues have been addressed in release 7.8. Users can get the latest release and more information on these issues, at the Toptech Systems security blog. https://www.toptech.com/blog/tms7-version-7-8-strengthens-security Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.5 LOW CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N 4.0 4.8 MEDIUM CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N Acknowledgments Sachin Shetty and Roy Duisters of Shell CyberDefence reported these vulnerabilities to Toptech and CISA. Legal Notice and Terms of Use This product is provided subject to this Notification ( https://www.cisa.gov/notification ) and this Privacy & Use policy ( https://www.cisa.gov/privacy-policy ). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-29 Date Revision Summary 2026-09-29 1 Initial Publication Legal Notice and Terms of Use

Indicators of Compromise (43)

CVE (10)
CVE-2026-71379
CVE-2026-70356
CVE-2026-72510
CVE-2026-63713
CVE-2026-68954
CVE-2026-68068
CVE-2026-72507
CVE-2026-71302
CVE-2026-69662
CVE-2026-71189
URL (29)
https://www.cve.org/CVERecord?id=CVE-2026-71379
https://www.toptech.com/blog/tms7-version-7-8-strengthens-security
https://cwe.mitre.org/data/definitions/552.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
https://www.cve.org/CVERecord?id=CVE-2026-70356
https://cwe.mitre.org/data/definitions/434.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
https://www.cve.org/CVERecord?id=CVE-2026-72510
https://cwe.mitre.org/data/definitions/89.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:L/A:H
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H
https://www.cve.org/CVERecord?id=CVE-2026-63713
https://www.cve.org/CVERecord?id=CVE-2026-68954
https://www.cve.org/CVERecord?id=CVE-2026-68068
https://www.cve.org/CVERecord?id=CVE-2026-72507
https://www.cve.org/CVERecord?id=CVE-2026-71302
https://cwe.mitre.org/data/definitions/384.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:L
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
https://www.cve.org/CVERecord?id=CVE-2026-69662
https://cwe.mitre.org/data/definitions/95.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
https://www.cve.org/CVERecord?id=CVE-2026-71189
https://cwe.mitre.org/data/definitions/79.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N
https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Domain (4)
www.toptech.com
cwe.mitre.org
www.first.org
Source Attribution

Originally published by CISA Advisories on Sep 29, 2026.

Related Threats

CRITICALPhishing

ABB Protection and Control IED Manager PCM600

<p><a href="https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-274-03.json"><strong>View CSAF</strong></a></p> <h2>Summary</h2> <p><strong>Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files.</strong></p> <p>The following versions of ABB Protection and Control IED Manager PCM600 are affected:</p> <ul> <li>Pro

CVE-2026-15952CVE-2026-15953
CISA Advisories
MEDIUMPhishing

Attackers Abuse MSP360 to Deploy ScreenConnect in Dual-RMM Phishing Attacks

Microsoft has warned of phishing campaigns distributing an installer for the MSP360 Remote Monitoring and Management (RMM) software under the guise of meeting invitations, PDF-themed lures, software update prompts, and other social-engineering content. "Once executed, the legitimate MSP360 installer, distributed under a deceptive file name established remote management access on affected

The Hacker News
MEDIUMPhishing

US-Focused CSuite Phishing Steals Microsoft 365 Sessions and Deploys RMM Tools for Remote Access

ANY.RUN researchers traced a US-focused CSuite phishing campaign across 351 sandbox analyses, with 51% of submissions coming from the United States. Technology, manufacturing, government, and consulting organizations showed the highest exposure. By combining Microsoft 365 session theft with remote-access tool deployment, CSuite can turn a phishing incident into broader account compromise, fraud

The Hacker News