CRITICALVulnerability
Global

Siemens Industrial Automation Software Products

·Source: CISA Advisories

Updated:

Executive Summary

View CSAF Summary On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is

Analysis

View CSAF Summary On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Automation Software Products are affected: COMOS Walkinside vers:all/* (CVE-2026-111497) gDAP (gPROMS Digital Application Platform) vers:all/* () Project Server Web Administration Tool vers:all/* (CVE-2026-111497) SIMATIC BRAUMAT vers:intdot/>=8.2.0.1| SIMATIC Profiling Tool vers:all/* (CVE-2026-111497) SIMATIC SISTAR vers:intdot/>=8.2.0.1| SIMATIC WinCC Companion vers:all/* (CVE-2026-111497) SIMATIC WinCC OA V3.20 vers:intdot/ SIMATIC WinCC OA V3.21 vers:all/* (CVE-2026-111497) SIMATIC WinCC Runtime Professional vers:all/* (CVE-2026-111497) SIMATIC WinCC Unified for Industrial Edge vers:all/* (CVE-2026-111497) SIMATIC WinCC Unified PC Runtime vers:all/* (CVE-2026-111497) SIMATIC WinCC Unified SIQENCE vers:all/* (CVE-2026-111497) SIMATIC WinCC V7/V8 vers:all/* (CVE-2026-111497) TIA Administrator vers:all/* (CVE-2026-111497) User Management Component (UMC) vers:all/* (CVE-2026-111497) CVSS Vendor Equipment v3 9.8 Siemens COMOS Walkinside 1 Vulnerability Out-of-bounds Write Background Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-111497 A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1. Read More 15 Affected Products COMOS Walkinside Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC Runtime Professional Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC Unified for Industrial Edge Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC Unified PC Runtime Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC Unified SIQENCE Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC V7/V8 Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available TIA Administrator Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. If UMC authentication is enabled, block requests that use Brotli compression: in IIS Manager, select the Default Web Site, open "Request Filtering" > "Rules", click "Add Filtering Rule", enter Name "CVE-2026-111497", Scan Headers "Content-Encoding" and Deny Strings "br", then click OK. None available Currently no fix is available User Management Component (UMC) Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required. In IIS Manager, select the Default Web Site, open "Request Filtering" > "Rules", click "Add Filtering Rule", enter Name "CVE-2026-111497", Scan Headers "Content-Encoding" and Deny Strings "br", then click OK. None available Currently no fix is available Project Server Web Administration Tool Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC BRAUMAT >= V8.2 Update 1 Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required Vendor fix Update to V8.2 Update 5 or later version SIMATIC Profiling Tool Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required No fix planned Currently no fix is planned SIMATIC SISTAR >= V8.2 Update 1 Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required Vendor fix Update to V8.2 Update 5 or later version SIMATIC WinCC Companion Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available SIMATIC WinCC OA V3.20 Product Status: known_affected, known_not_affected Remediations Vendor fix Update to V3.20 P17.1 or later version SIMATIC WinCC OA V3.21 Product Status: known_affected, known_not_affected Remediations Mitigation Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required None available Currently no fix is available Additional Metrics Relevant CWE: CWE-787 Out-of-bounds Write CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet . Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics . Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies . CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets . Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies . Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-242944 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-11-10 Date Revision Summary 2026-11-10 1 Publication Date 2026-11-17 2 Initial CISA Republication of Siemens ProductCERT SSA-242944 advisory Legal Notice and Terms of Use

Indicators of Compromise (15)

CVE (1)
CVE-2026-111497
URL (7)
https://cwe.mitre.org/data/definitions/787.html
https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
https://www.cve.org/CVERecord?id=CVE-2026-111497
https://www.siemens.com/cert/operational-guidelines-industrial-security),
https://www.siemens.com/industrialsecurity
https://www.siemens.com/cert/advisories
https://www.siemens.com/productcert/terms-of-use.
Domain (4)
cwe.mitre.org
www.first.org
www.siemens.com
Source Attribution

Originally published by CISA Advisories on Nov 17, 2026.

Related Threats

CRITICALVulnerability

Siemens Industrial Software Products

<p><a href="https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-321-04.json"><strong>View CSAF</strong></a></p> <h2>Summary</h2> <p><strong>On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is

CVE-2026-111497
CISA Advisories
CRITICALVulnerability

Siemens Desigo, Gridscale

<p><a href="https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-316-02.json"><strong>View CSAF</strong></a></p> <h2>Summary</h2> <p><strong>On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as "Node2Shell" (tracked as CVE-2026-111497). The vulnerability is

CVE-2026-111497
CISA Advisories
MEDIUMVulnerability

PHP2Shell and Node2Shell: Find, Fix, and Verify Across Your Web Apps and APIs

Key Takeaways Neither flaw is in your application code. Every app and API on a vulnerable runtime inherits the risk. PHP2Shell (CVE-2026-109618, CVE-2026-109619) is fixed in PHP 8.5.12, 8.4.27, 8.3.36, and 8.2.35. Node2Shell (CVE-2026-111497) is fixed in Node.js 22.23.4, 24.22.1, and 26.12.1. Both are on the CISA KEV list. PHP2Shell was added October 26. Node2Shell [&#8230;]

CVE-2026-109618CVE-2026-109619